20 BIM collections found from 5 manufacturer(s) in Vereinigte Staaten
Victaulic cULus-FM Version

cULus-FM Version

Firelock alarm check valve

Victaulic

cULus-FM Version

Firelock alarm check valve

EMCS-Kompatibilität

.DWG .RFA

Ventil

Victaulic

Herunterladen
Victaulic European Trim

European Trim

Alarm Check Valve

Victaulic

European Trim

Alarm Check Valve

EMCS-Kompatibilität

.DWG .RFA

Ventil

Victaulic

Herunterladen
Oventrop Valve Disc with FKM Seal

Valve Disc with FKM Seal

Bronze piston type spring assisted check valve

Oventrop

Valve Disc with FKM Seal

Bronze piston type spring assisted check valve

EMCS-Kompatibilität

.DWG .RFA .IFC

Ventil

Oventrop

Herunterladen
Caleffi 521A

521A

Instelbare thermostatische en drukgebalancerde mengkraan

Caleffi

521A

Instelbare thermostatische en drukgebalancerde mengkraan

EMCS-Kompatibilität

.DWG .RFA .IFC

Einstellbar

Caleffi

Herunterladen
Caleffi Adjustable Thermostatic and Pressure Balanced Mixing Valve

Adjustable Thermostatic and Pressure Balanced Mixing Valve

Stable mixed temperature performance with durable construction for long life. Due to the unique mixing chamber design, Caleffi MixCal™ produces very stable mixed water temperature as inlet temperatures and pressures vary. Scale formation is minimized via sliding surfaces constructed of an anti-scale polymer, thus guarding against seizing or erratic mixed temperatures. O-ring seals made from durable peroxide-cured EPDM resist wear from common water treatment additives such as chlorine and chloramines.

Caleffi

Adjustable Thermostatic and Pressure Balanced Mixing Valve

Stable mixed temperature performance with durable construction for long life. Due to the unique mixing chamber design, Caleffi MixCal™ produces very stable mixed water temperature as inlet temperatures and pressures vary. Scale formation is minimized via sliding surfaces constructed of an anti-scale polymer, thus guarding against seizing or erratic mixed temperatures. O-ring seals made from durable peroxide-cured EPDM resist wear from common water treatment additives such as chlorine and chloramines.

EMCS-Kompatibilität

.DWG .RFA .IFC

Ventil

Caleffi

Herunterladen
Caleffi 1164A THERMOSETTER™ Thermal Balancing Valve

1164A THERMOSETTER™ Thermal Balancing Valve

Adjustable thermal balancing valve for domestic hot water recirculation circuits.

Caleffi

1164A THERMOSETTER™ Thermal Balancing Valve

Adjustable thermal balancing valve for domestic hot water recirculation circuits.

EMCS-Kompatibilität

.DWG .RFA .IFC

Elektronisches Mischventil

Caleffi

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe FDU-KXE6F-W

FDU-KXE6F-W

VRF ducted high static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

Mitsubishi Heavy Industries Air Conditioning Europe

FDU-KXE6F-W

VRF ducted high static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe FDUM-KXE6F-W

FDUM-KXE6F-W

VRF ducted low/middle static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

Mitsubishi Heavy Industries Air Conditioning Europe

FDUM-KXE6F-W

VRF ducted low/middle static pressure - Indoor unit (R32) - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa - Installation flexibility as thin design with 280mm height - Standard built- in drain pump - Transparent access hole to drain pan to check the drain pan without removing drain pan - Reduced energy consumption by applying DC fan motor

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe FDTW-KXE6F

FDTW-KXE6F

Ceiling Cassette-2way - Indoor Unit - According to room temperature conditions, four directions air flow can be controlled individually by flap control system. - Due to optimization of outlet design of air flow our new advanced technology, sufficient air flow is secured and long reach of air flow is achieved. - The flap can swing within the range of upper and lower flap position selected with wired remote control. - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Standard built- in drain pump.

Mitsubishi Heavy Industries Air Conditioning Europe

FDTW-KXE6F

Ceiling Cassette-2way - Indoor Unit
- According to room temperature conditions, four directions air flow can be controlled individually by flap control system.
- Due to optimization of outlet design of air flow our new advanced technology, sufficient air flow is secured and long reach of air flow is achieved.
- The flap can swing within the range of upper and lower flap position selected with wired remote control.
- Transparent access hole to drain pan to check the drain pan without removing drain pan.
- Standard built- in drain pump.

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe FDU-KXE6F

FDU-KXE6F

Duct Connected-High static pressure - Indoor Unit - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 200 Pa. - Installation flexibility as thin design with 280mm height. - Standard built- in drain pump, - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Reduced energy consumption by applying DC fan motor. - Reduction of sound pressure level down to 25dBA.

Mitsubishi Heavy Industries Air Conditioning Europe

FDU-KXE6F

Duct Connected-High static pressure - Indoor Unit
- Adjustable external static pressure by wired remote controller
- Wide external static pressure: from 10 to 200 Pa.
- Installation flexibility as thin design with 280mm height.
- Standard built- in drain pump,
- Transparent access hole to drain pan to check the drain pan without removing drain pan.
- Reduced energy consumption by applying DC fan motor.
- Reduction of sound pressure level down to 25dBA.

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe FDUM-KXE6F

FDUM-KXE6F

Duct Connected-Low/Middle Static Pressure - Indoor Unit - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa. - Installation flexibility as thin design with 280mm height. - Standard built- in drain pump, - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Reduced energy consumption by applying DC fan motor. - Reduction of sound pressure level down to 25dBA.

Mitsubishi Heavy Industries Air Conditioning Europe

FDUM-KXE6F

Duct Connected-Low/Middle Static Pressure - Indoor Unit - Adjustable external static pressure by wired remote controller - Wide external static pressure: from 10 to 100 Pa. - Installation flexibility as thin design with 280mm height. - Standard built- in drain pump, - Transparent access hole to drain pan to check the drain pan without removing drain pan. - Reduced energy consumption by applying DC fan motor. - Reduction of sound pressure level down to 25dBA.

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDU71-140VH

PAC-FDU71-140VH

Duct Connected - High static pressure - Indoor unit - Adjustable external static pressure by wired remote controller from 10 to 200 Pa - Energy efficiency is improved by using DC fan motor & high efficient heat exchanger - Zoning system: effective temperatures control of multiple rooms with one indoor duct unit - Quiet operation (sound pressure level of 37-38 dBA) is achieved thanks to DC fan motor - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side - Drain-pump (600 mm) is mounted in all models and the drain pan is equipped with a window to quickly check the cleanliness - Compatible with R410 and R32 refrigerants

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDU71-140VH

Duct Connected - High static pressure - Indoor unit - Adjustable external static pressure by wired remote controller from 10 to 200 Pa - Energy efficiency is improved by using DC fan motor & high efficient heat exchanger - Zoning system: effective temperatures control of multiple rooms with one indoor duct unit - Quiet operation (sound pressure level of 37-38 dBA) is achieved thanks to DC fan motor - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side - Drain-pump (600 mm) is mounted in all models and the drain pan is equipped with a window to quickly check the cleanliness - Compatible with R410 and R32 refrigerants

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
Mitsubishi Heavy Industries Air Conditioning Europe PAC-FDUM40-140VH

PAC-FDUM40-140VH

Duct Connected - Low/Middle Static Pressure - Indoor unit - Thin design with a height of only 280 mm for all the models - Zoning system: effective temperatures control of multiple rooms with one indoor duct unit - Automatic External Static Pressure control: indoor unit will automatically recognize ESP by itself and keep the rated air flow volume - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side - Drain-pump (600 mm) is mounted in all models and the drain pan is equipped with a window to quickly check the cleanliness - Compatible with R410 and R32 refrigerants

Mitsubishi Heavy Industries Air Conditioning Europe

PAC-FDUM40-140VH

Duct Connected - Low/Middle Static Pressure - Indoor unit - Thin design with a height of only 280 mm for all the models - Zoning system: effective temperatures control of multiple rooms with one indoor duct unit - Automatic External Static Pressure control: indoor unit will automatically recognize ESP by itself and keep the rated air flow volume - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side - Drain-pump (600 mm) is mounted in all models and the drain pan is equipped with a window to quickly check the cleanliness - Compatible with R410 and R32 refrigerants

EMCS-Kompatibilität

.DWG .RFA .IFC

Klimaanlage

Mitsubishi Heavy Industries Air Conditioning Europe

Herunterladen
Caleffi QuickSetter+™ Balancing Valve

QuickSetter+™ Balancing Valve

The QuickSetter+™ manual balancing valve contains a built-in flow meter and sight gauge, negating the need for differential pressure gauges and reference charts. Circuit balancing is fast, easy and accurate. Constructed of DZR low-lead brass, QuickSetter+ is ideally suited for use in plumbing applications such as hot water recirculation systems. The built-in check valve protects against circuit thermo-siphoning. The outlet dual-scale temperature gauge (optional) verifies the fluid temperature in the circuit. The flow meter sight gauge is dry (not exposed to the fluid) thus eliminating the possibility of gauge clouding/scaling over time. The QuickSetter+ can also be used in heating systems. Peroxide-cured EPDM seals provide chlorine and chloramine resistance and long operating life.

Caleffi

QuickSetter+™ Balancing Valve

The QuickSetter+™ manual balancing valve contains a built-in flow meter and sight gauge, negating the need for differential pressure gauges and reference charts. Circuit balancing is fast, easy and accurate. Constructed of DZR low-lead brass, QuickSetter+ is ideally suited for use in plumbing applications such as hot water recirculation systems. The built-in check valve protects against circuit thermo-siphoning. The outlet dual-scale temperature gauge (optional) verifies the fluid temperature in the circuit. The flow meter sight gauge is dry (not exposed to the fluid) thus eliminating the possibility of gauge clouding/scaling over time. The QuickSetter+ can also be used in heating systems. Peroxide-cured EPDM seals provide chlorine and chloramine resistance and long operating life.

EMCS-Kompatibilität

.DWG .RFA .IFC

Ventil

Caleffi

Herunterladen
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS-Kompatibilität

.RFA

Verteiler für Zentralheizung

IVAR

Herunterladen
Caleffi LEGIOMIX® Station 6000AS series Electronic Mixing Valve

LEGIOMIX® Station 6000AS series Electronic Mixing Valve

The LEGIOMIX® electronic mixing valve provides precise temperature control over very low and very high flow rate demand, minimal pressure drop with a ball valve control element, automatic self-cleaning to prevent scale formation and easy-to-use digital interface with data logging, alarming and status indication. The LEGIOMIX electronic mixing valve is furnished with a controller with LCD user interface that provides a set of programs for circuit thermal disinfection to kill Legionella. The controller is configurable via keypad, or local or remote computer. Depending on the type of system and habits of the user, temperature levels and operation times can be programmed as desired. In addition, it comes standard with monitoring and remote control connections.The LEGIOMIX Station is pre-piped with LEGIOMIX 3-way mixing valve with union connections, serviceable low-lead stainless steel check valves, a recirculation connection and low-lead isolation valves for fast and simple installation. The LEGIOMIX controller is pre-mounted and pre-wired to the valve actuator, return water temperature sensor and tempered water sensor in a packaged wall mount configuration with steel uni-strut frame that can bolt to the wall through any of the perforations. The assembly also includes copper type L pipe and a 24 VAC transformer.The LEGIOMIX6000 series electronic mixing valve complies with the requirements of NSF/ANSI 372-2016 as certified by ICC-ES, and is certified to ASSE 1017, CSA B125.3, UPC, IPC, Low Lead Laws and listed by ICC-ES for use in accordance with the U.S. and Canadian plumbing codes. The valve meets the requirement of CSA Z317.1 Special Requirement for Plumbing Installations in Health Care Facilities, certified by ICC-ES.

Caleffi

LEGIOMIX® Station 6000AS series Electronic Mixing Valve

The LEGIOMIX® electronic mixing valve provides precise temperature control over very low and very high flow rate demand, minimal pressure drop with a ball valve control element, automatic self-cleaning to prevent scale formation and easy-to-use digital interface with data logging, alarming and status indication. The LEGIOMIX electronic mixing valve is furnished with a controller with LCD user interface that provides a set of programs for circuit thermal disinfection to kill Legionella. The controller is configurable via keypad, or local or remote computer. Depending on the type of system and habits of the user, temperature levels and operation times can be programmed as desired. In addition, it comes standard with monitoring and remote control connections.The LEGIOMIX Station is pre-piped with LEGIOMIX 3-way mixing valve with union connections, serviceable low-lead stainless steel check valves, a recirculation connection and low-lead isolation valves for fast and simple installation. The LEGIOMIX controller is pre-mounted and pre-wired to the valve actuator, return water temperature sensor and tempered water sensor in a packaged wall mount configuration with steel uni-strut frame that can bolt to the wall through any of the perforations. The assembly also includes copper type L pipe and a 24 VAC transformer.The LEGIOMIX6000 series electronic mixing valve complies with the requirements of NSF/ANSI 372-2016 as certified by ICC-ES, and is certified to ASSE 1017, CSA B125.3, UPC, IPC, Low Lead Laws and listed by ICC-ES for use in accordance with the U.S. and Canadian plumbing codes. The valve meets the requirement of CSA Z317.1 Special Requirement for Plumbing Installations in Health Care Facilities, certified by ICC-ES.

EMCS-Kompatibilität

.DWG .RFA .IFC

Geräte

Caleffi

Herunterladen
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

EMCS-Kompatibilität

.RVT .RFA

Verteiler für Zentralheizung

IVAR

Herunterladen