19 BIM collections found from 7 manufacturer(s) in Statele Unite ale Americii
Standard Cable Penetration Unit

Cable Penetration Unit

Cable penetration unit

Standard

Cable Penetration Unit

Cable penetration unit

Conform cu EMCS

.DWG .RFA .IFC

Treceri de cablu

Standard

Descărcare
Legrand Legrand GWO 6

Legrand GWO 6

Families of Legrand GWO 6 Wall trays

Legrand

Legrand GWO 6

Families of Legrand GWO 6 Wall trays

Conform cu EMCS

.RFA

Fitinguri - Electrice

Legrand

Descărcare
Spelsberg WKE 2

WKE 2

Cable junction box

Spelsberg

WKE 2

Cable junction box

Conform cu EMCS

.DWG .RFA .IFC

Doze conexiuni

Spelsberg

Descărcare
Spelsberg WKE 4

WKE 4

Cable junction box

Spelsberg

WKE 4

Cable junction box

Conform cu EMCS

.DWG .RFA .IFC

Doze conexiuni

Spelsberg

Descărcare
Spelsberg WKE 6

WKE 6

Cable junction box

Spelsberg

WKE 6

Cable junction box

Conform cu EMCS

.DWG .RFA .IFC

Doze conexiuni

Spelsberg

Descărcare
Legrand Lexic XL3 800

Lexic XL3 800

XL3 800 external cable sleeve

Legrand

Lexic XL3 800

XL3 800 external cable sleeve

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

Legrand

Descărcare
Spelsberg WKE-LSA

WKE-LSA

Cable junction box WKE-LSA

Spelsberg

WKE-LSA

Cable junction box WKE-LSA

Conform cu EMCS

.RFA

Doze conexiuni

Spelsberg

Descărcare
Spelsberg WKE-RK

WKE-RK

Cable junction box WKE-RK

Spelsberg

WKE-RK

Cable junction box WKE-RK

Conform cu EMCS

.RFA

Doze conexiuni

Spelsberg

Descărcare
Legrand Lexic XL3 400

Lexic XL3 400

XL3 400 external cable sleeve plastic

Legrand

Lexic XL3 400

XL3 400 external cable sleeve plastic

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

Legrand

Descărcare
Siegenia AEROMAT VT WRG

AEROMAT VT WRG

AEROMAT VT WRG 1000/1100: The "smart" version of AEROMAT VT with heat recovery is equipped with WLAN control. Thus it can be easily and conveniently operated by smartphone or tablet via the SIEGENIA Comfort app.

Siegenia

AEROMAT VT WRG

AEROMAT VT WRG 1000/1100: The "smart" version of AEROMAT VT with heat recovery is equipped with WLAN control. Thus it can be easily and conveniently operated by smartphone or tablet via the SIEGENIA Comfort app.

Conform cu EMCS

.DWG .RFA .IFC

Schimbătoare de căldură - Ventilare

Siegenia

Descărcare
Legrand Lexic XL3 800

Lexic XL3 800

XL3 800 external cable sleeve

Legrand

Lexic XL3 800

XL3 800 external cable sleeve

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

Legrand

Descărcare
Legrand XL3 S 630

XL3 S 630

Cable duct for XL³S 630

Legrand

XL3 S 630

Cable duct for XL³S 630

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

Legrand

Descărcare
Legrand Lexic XL3 400

Lexic XL3 400

XL3 400 external cable sleeve wall

Legrand

Lexic XL3 400

XL3 400 external cable sleeve wall

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

Legrand

Descărcare
Legrand Lexic XL3 400

Lexic XL3 400

XL3 400 external cable sleeve floor

Legrand

Lexic XL3 400

XL3 400 external cable sleeve floor

Conform cu EMCS

.DWG .RFA .IFC

Cofrete electrice

Legrand

Descărcare
Haws corporation Model 8317CTFP

Model 8317CTFP

Model 8317CTFP, 120 VAC cable heated, freeze protected, combination shower and eye/face wash, with top or bottom supply, and with AXION® MSR eye/face wash and showerhead.

Haws corporation

Model 8317CTFP

Model 8317CTFP, 120 VAC cable heated, freeze protected, combination shower and eye/face wash, with top or bottom supply, and with AXION® MSR eye/face wash and showerhead.

Conform cu EMCS

.RFA

Dușuri de urgență

Haws corporation

Descărcare
Mitsubishi Heavy Industries Air Conditioning Europe PFD

PFD

PFD refrigerant flow branch control. -Easy installation, New PFD design means the connection of the indoor unit liquid pipe is made directly to the liquid line - bypassing the PFD. This means (x2) less pipe connections per indoor unit, reducing installation time and cost. -Optional PFD box extension cable that has a connector at ends makes it possible to separate the indoor unit and PFD box further, enable the PFD box to be located away from the indoor unit help reducing the influence of sound caused by PFD box and refrigerant flow.

Mitsubishi Heavy Industries Air Conditioning Europe

PFD

PFD refrigerant flow branch control.
-Easy installation, New PFD design means the connection of the indoor unit liquid pipe is made directly to the liquid line - bypassing the PFD. This means (x2) less pipe connections per indoor unit, reducing installation time and cost.
-Optional PFD box extension cable that has a connector at ends makes it possible to separate the indoor unit and PFD box further, enable the PFD box to be located away from the indoor unit help reducing the influence of sound caused by PFD box and refrigerant flow.

Conform cu EMCS

.DWG .RFA .IFC

Unități de control - Termice

Mitsubishi Heavy Industries Air Conditioning Europe

Descărcare
IVAR UNIMIX / UNIMIX-C

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

IVAR

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

Conform cu EMCS

.RVT .RFA

Unități de control - Termice

IVAR

Descărcare
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

Conform cu EMCS

.RVT .RFA

Distribuitoare - Termice

IVAR

Descărcare
Legrand Legrand Soluflex Placi de Ieșire

Legrand Soluflex Placi de Ieșire

Placi de ieșire de Soluflex pentru mufa de cablu Legrand

Legrand

Legrand Soluflex Placi de Ieșire

Placi de ieșire de Soluflex pentru mufa de cablu Legrand

Conform cu EMCS

.RFA

Sisteme de montare - Electrice

Legrand

Descărcare