61 BIM collections found from 1 manufacturer(s) in United States Of America
IVAR Modular manifolds EASY-RADIANT

Modular manifolds EASY-RADIANT

Modular return manifold EASY RADIANT series (centre-to-centre distance 40 mm) with isolation valves with protection cap for

IVAR

Modular manifolds EASY-RADIANT

Modular return manifold EASY RADIANT series (centre-to-centre distance 40 mm) with isolation valves with protection cap for

EMCS compliant

.RVT .RFA

Manifold

IVAR

Download
IVAR POLIFEMO® / POLIFEMO® PLUS

POLIFEMO® / POLIFEMO® PLUS

IVAR POLIFEMO® cod. 520150: Spherical crystal polyphosphate and silicate doser with integrated safety filter to protect the system from limescale and corrosion. To be installed vertically or horizontally on the cold water pipe upstream of the domestic hot water producer (boiler, water heater, etc.) or upstream of the appliance to be protected (washing machine, dishwasher). Chemical compounds proportionally dosed thanks to the calibrated consumption of the spheres according to the quantity of water that passes through the component. Float with refill indicator for cartridge replacement. Threaded body in chromed brass CW617N, glass in Grilamid® TR, sealing elements in peroxide EPDM. Flow coefficient Kv= 2,15 m3/h, maximum flow rate 25 l/min (with ΔP = 0,5 bar). Size of the polypropylene safety filter: 100 μm. Temperature: 0÷40 °C. Maximum working pressure: 10 bar. Volume of water treated with one refill: about 30 m3. Connections: 1/2 "F (x3). IVAR POLIFEMO® PLUS cod. 520151: Spherical crystal polyphosphate and silicate doser with integrated safety filter to protect the system from limescale and corrosion. To be installed vertically or horizontally on the cold water pipe upstream of the domestic hot water producer (boiler, water heater, etc.) or upstream of the appliance to be protected (washing machine, dishwasher). Chemical compounds proportionally dosed thanks to the calibrated consumption of the spheres according to the quantity of water that passes through the component. Float with refill indicator for cartridge replacement. Threaded body in chromed brass CW617N, glass in Grilamid® TR, sealing elements in peroxide EPDM. Flow coefficient Kv= 1,10 m3/h, maximum flow rate 13 l/min (with ΔP = 0,5 bar). Size of the polypropylene safety filter: 100 μm. Temperature: 0÷40 °C. Maximum working pressure: 10 bar. Volume of water treated with one refill: about 30 m3. Connections: 1/2 "F (x3). Integrated by-pass to replace the cartridge without interrupting the water supply to the system.

IVAR

POLIFEMO® / POLIFEMO® PLUS

IVAR POLIFEMO® cod. 520150: Spherical crystal polyphosphate and silicate doser with integrated safety filter to protect the system from limescale and corrosion. To be installed vertically or horizontally on the cold water pipe upstream of the domestic hot water producer (boiler, water heater, etc.) or upstream of the appliance to be protected (washing machine, dishwasher). Chemical compounds proportionally dosed thanks to the calibrated consumption of the spheres according to the quantity of water that passes through the component. Float with refill indicator for cartridge replacement. Threaded body in chromed brass CW617N, glass in Grilamid® TR, sealing elements in peroxide EPDM. Flow coefficient Kv= 2,15 m3/h, maximum flow rate 25 l/min (with ΔP = 0,5 bar). Size of the polypropylene safety filter: 100 μm. Temperature: 0÷40 °C. Maximum working pressure: 10 bar. Volume of water treated with one refill: about 30 m3. Connections: 1/2 "F (x3). IVAR POLIFEMO® PLUS cod. 520151: Spherical crystal polyphosphate and silicate doser with integrated safety filter to protect the system from limescale and corrosion. To be installed vertically or horizontally on the cold water pipe upstream of the domestic hot water producer (boiler, water heater, etc.) or upstream of the appliance to be protected (washing machine, dishwasher). Chemical compounds proportionally dosed thanks to the calibrated consumption of the spheres according to the quantity of water that passes through the component. Float with refill indicator for cartridge replacement. Threaded body in chromed brass CW617N, glass in Grilamid® TR, sealing elements in peroxide EPDM. Flow coefficient Kv= 1,10 m3/h, maximum flow rate 13 l/min (with ΔP = 0,5 bar). Size of the polypropylene safety filter: 100 μm. Temperature: 0÷40 °C. Maximum working pressure: 10 bar. Volume of water treated with one refill: about 30 m3. Connections: 1/2 "F (x3). Integrated by-pass to replace the cartridge without interrupting the water supply to the system.

EMCS compliant

.RVT .RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR MULTIMIX

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

IVAR

MULTIMIX

Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with: - Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h. - High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar. - Variable-speed electronic pump WILO4F centre distance 130 mm. - 3-speed standard pump WILO3F centre distance 130 mm. - Polypropylene insulation shell. - Wall fitted cabinet with variable height and depth. - T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m. - RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.

EMCS compliant

.RVT .RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR UNIMIX / UNIMIX-C

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

IVAR

UNIMIX / UNIMIX-C

Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with: UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar. AUM 03: expanded polypropylene insulating cover. T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m. RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display. AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side. AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side. AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.

EMCS compliant

.RVT .RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR COMBIMIX

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

IVAR

COMBIMIX

Mixing and boosting unit IVAR COMBIMIX for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), two shut-off ball valves for the pump, two fill/drain valves, two automatic air vent valves, three thermometers 0÷80 °C (on delivery and return of boiler circuit and on delivery of mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut-off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M with swivelling nipples (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T5011 included (max differential pressure at mixing valve ends 250 mbar) or set up for outside compensated temperature mixing by integrating axial servomotor IVAR RV 01 or thermoelectric actuator IVAR TE 3061. Differential bypass valve (optional) 0.2÷0.6 bar with half-hard nickel-plated pipe. Pump space 130 mm or 180 mm, G 1”1/2F flat seal connections. Equipped with variable-speed electronic pump WILO4F or variable-speed electronic pump WILO4F-180 or without pump. Accessories: high-temperature kit with pair of manifolds 1” x EUROK with shut-off and lockshield valves CEP/02 I – CEP/03 I (2 ways) – (3 ways), high-temperature kit with pair of simple manifolds 1” x EUROK CEP/02 – CEP/03 (2 ways) – (3 ways), insulation shell ACM 01, threaded spacer for pumps AC 633.

EMCS compliant

.RVT .RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR Dirtstop® XL

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

IVAR

Dirtstop® XL

IVAR Dirtstop® XL: triple effect magnetic dirt separator: cyclonic action guaranteed by a patented internal insert, developed to guide the fluid directed to the boiler in order to maximize the slowing down and decantation of the debris; subsequent removal of ferrous particles by means of a neodymium magnet, magnetic field 14000 G; mechanical filtration with an 800 μm mesh filter (pre- assembled 500 μm filter for the first cleaning of the system). Internal components completely inspectable, removable and washable by removing the upper plug, with the special lever provided. Manual air vent valve. Draining valve with opening lever and tap. Swivel fitting for mounting to the pipeline in different orientations, with the special lever provided. Allowed installation on horizontal, vertical or oblique lines. Buttonhole on magnetic insert, sealing band supplied. Materials: body, cyclonic insert and cap in PA66 + GF 30%; "T" joint and locking ring nut in PA66 + GF 30%; filters in stainless steel AISI 304; seals in peroxide EPDM. Compatible fluids: water; water + glycol max 50%. Maximum recommended flow rate: 2.13 m3/h. Maximum operating pressure: 3 bar. Operating temperature: 0-90 °C. Flow coefficient Kv: 6.7 m3 /h. Connections: Ø22 x Ø22 copper pipe (520124); 3/4" F x 3/4" F (520135); 1"F x 1" F (520136); 1"1/4 F x 1"1/4 F (520139).

EMCS compliant

.RVT .RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR RTV Thermostatic Valve For Recirculation Branch Balancing

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: thermostatic valve for controlling the water temperature in the recirculation branches. Balancing thermostatic insert with fixed point adjustment settable with graduated knob equipped with locking mechanism. Version A with only recirculation branch balancing. Version B with thermostatic control for thermal disinfection cycle. Version C with electronic thermal disinfection cycle. Connections: 1/2" F or 3/4" F. Adjustment range 35-60 °C. ΔP maximum at the ends of the valve 1 bar. Main material: brass CW617N. Adjustment knob: ABS. O-ring seal: peroxide EPDM.

IVAR

RTV Thermostatic Valve For Recirculation Branch Balancing

IVAR RTV: thermostatic valve for controlling the water temperature in the recirculation branches. Balancing thermostatic insert with fixed point adjustment settable with graduated knob equipped with locking mechanism. Version A with only recirculation branch balancing. Version B with thermostatic control for thermal disinfection cycle. Version C with electronic thermal disinfection cycle. Connections: 1/2" F or 3/4" F. Adjustment range 35-60 °C. ΔP maximum at the ends of the valve 1 bar. Main material: brass CW617N. Adjustment knob: ABS. O-ring seal: peroxide EPDM.

EMCS compliant

.RVT .RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VARIMIX

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

IVAR

VARIMIX

Distribution and mixing system IVAR VARIMIX for thermal power stations, modular with: hydraulic separator, modular distribution manifold, high-temperature direct flow kit, low-temperature mixing kit, motor for mixing valves, expansion tank, motor for zone ball zone valves. VARIMIX allows to arrange the mechanical room according to a new concept of space and functionality. This solution gives the opportunity to manage multiple thermal areas with different characteristics as truly independent zones in a neat, rational space, thanks to its modular structure and outstanding installation flexibility. In low temperature kits, the mixer valve is available with different hydraulic features and in 3-way or 4-way versions. By producing a mixture even on the return line, it is particularly suitable for older boilers where the return temperature must not be too low to avoid corrosion. Finally, the “LT” modules are specifically designed for applications with low temperature heat sources (for example, heat pumps). Main features: easy to install; compact and neat; fully reversible; versatile and flexible; suitable for heating and cooling applications. Max primary flow rate: 4500 l/h. Max flow rate for each kit: 3000 l/h.

EMCS compliant

.RVT .RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR Fan-Coil Unit Kit

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

IVAR

Fan-Coil Unit Kit

IVAR FCU-Kit: Pre-assembled brass multi-function bypass unit for fan-coil systems, chilled beams, heaters and other constant flow rate conditioning systems. Can be used for both heating and cooling. Consisting of: a pair of three-way valves for setting 5 different operating modes, a mesh filter, two loading/unloading taps, a Venturi orifice with a pair of piezometric sockets and a PICV flow regulator. Permissible differential pressure ranges and flow control range (for PICV): with PICC 03 cartridge (code 590123) 16- 200 kPa, 37-575 l/h; with PICC 03 cartridge (code 590124) 30-400 kPa, 64-1110 l/h. Mesh filter (500 μm) in stainless steel AISI 304. Connections to the primary circuit (with unions): 1/2 "F (DN 15) - 3/4 "F (DN 20). Connections to the secondary circuit: 1/2 "F (DN 15) - 3/4 "F (DN 20). Maximum operating pressure: 10 bar. Maximum operating temperature: 120 °C. Available with insulation shell in grey ARPRO 5135 FR with conductivity 0.037 W/mK, density 50 kg/m3, reaction to fire class HF-1 according to UL-94 standard.

EMCS compliant

.RVT .RFA

Fan Coil Unit

IVAR

Download
IVAR TECHNOMIX

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

IVAR

TECHNOMIX

IVAR TECHNO TNB cod. 508100: mixing and boosting unit for radiant installations complete with two-way mixing valve, balancing valve (on the cold way), fill/drain valve, manual air vent valve, two thermometers 0÷80 °C (on delivery of boiler circuit and mixed circuit), temperature sensor pocket (on delivery of mixed circuit), shut off valve (on return of boiler circuit), boiler circuit connections G 1”F (centre distance 200 mm) and mixed circuit connections G 1”M (centre distance 200 mm). Upper and lower parts made of nickel-plated CB753S brass; pipe made of nickel-plated half-hard copper; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Fixed point mixing 20÷60 °C by thermostatic control head with remote sensor T3011 included. Max differential pressure at mixing valve ends 250 mbar. Pump space 130 mm with G 1”1/2F flat seal connections.

EMCS compliant

.RVT .RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR Dirtstop®

Dirtstop®

IVAR Dirtstop®: Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swiveling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the large settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swiveling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swiveling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swiveling insert in position A = 5,6 m3/h angle configuration; Kv with swiveling insert in position A1 = 6,2 m3/h straight configuration; Kv with swiveling insert in position B = 5,5 m3/h angle configuration; Kv with swiveling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

IVAR

Dirtstop®

IVAR Dirtstop®: Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swiveling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the large settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swiveling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swiveling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swiveling insert in position A = 5,6 m3/h angle configuration; Kv with swiveling insert in position A1 = 6,2 m3/h straight configuration; Kv with swiveling insert in position B = 5,5 m3/h angle configuration; Kv with swiveling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

EMCS compliant

.RVT .RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR EQCP1 Equicompact Metering Module

EQCP1 Equicompact Metering Module

IVAR EQCP1 (Kv 2.50): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506587CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506587CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C. IVAR EQCP1 (Kv 3.00): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 130 mm and nominal flow rate Qnom = 2.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506539CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506539CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.

IVAR

EQCP1 Equicompact Metering Module

IVAR EQCP1 (Kv 2.50): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506587CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506587CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C. IVAR EQCP1 (Kv 3.00): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 130 mm and nominal flow rate Qnom = 2.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506539CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506539CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.

EMCS compliant

.RVT .RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR PICV 00-05-10 With PICC 01-02-03

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 00-05-10 With PICC 01-02-03

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 00 (female) connections: G 1/2"F, G 3/4"F, G 1"F in compliance with ISO 228/1. PICV 05 (male - flat seal) connections: G 3/4"M, EUROK, G 1"M, G 1"1/4M in compliance with ISO 228/1. PICV 10 (with unions) connections: G 1/2"M, G 3/4"M, G 1"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 01, PICC 02 or PICC 03 cartridges. PICC connection: M32x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 03: 6 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 01: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 02: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 03: 41 flow rate ranges to set even during operation; to combine with IVAR TE 3003 electrothermal actuator (M30x1.5; ON/OFF 230 V AC or ON/OFF 24 V AC or proportional 0-10 V 24 V AC adjustment) or IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 6 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR LEGIO-BOX 3

LEGIO-BOX 3

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Dimensions (W x H x D): 295 x 290 x 75 mm.

IVAR

LEGIO-BOX 3

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Dimensions (W x H x D): 295 x 290 x 75 mm.

EMCS compliant

.RFA

Control Panel

IVAR

Download
IVAR LEGIO-BOX 2

LEGIO-BOX 2

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Box dimensions (W x H x D): 500 x 350 x 90 mm.

IVAR

LEGIO-BOX 2

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass. Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: 3/4" M. Box dimensions (W x H x D): 500 x 350 x 90 mm.

EMCS compliant

.RFA

Control Panel

IVAR

Download
IVAR LEGIO-BOX 1

LEGIO-BOX 1

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with manifolds, box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass (externally zinc-plated). Manifolds material: CW617N brass (externally zinc-plated). Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: EUROK. Box dimensions (W x H x D): 500 x 350 x 90 mm.

IVAR

LEGIO-BOX 1

Temperature control and thermal disinfection multifunctional unit for sanitary systems. It allows the temporary by-pass of the thermostatic mixing valve to supply high-temperature water to the system terminal units for the thermal disinfection. Provided with/without thermoelectric actuator on the three-way valve, with manifolds, box and fastening kit. Shut-off ball valves at the inlets. Thermoelectric actuator: ON/OFF 230 V AC normally closed (2 wires). Max fluid temperature: 90° C. Maximum operating pressure: 10 bar. Max pressure differential at three-way valve ends: 1 bar. Main body material: CW617N brass (externally zinc-plated). Manifolds material: CW617N brass (externally zinc-plated). Box material: high impact polystyrene. Branches material: copper. Sealing elements material: Peroxide EPDM. Inlet connections: 3/4” F. Outlet connections: EUROK. Box dimensions (W x H x D): 500 x 350 x 90 mm.

EMCS compliant

.RFA

Control Panel

IVAR

Download
IVAR PICV 200-205-210 With PICC 22

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 200-205-210 With PICC 22

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 200 (female) connections: G 1"1/2F, G 2"F in compliance with ISO 228/1. PICV 205 (male - flat seal) connections: G 2"M, G 2"1/2M in compliance with ISO 228/1. PICV 210 (with unions) connections: G 1"1/2M, G 2"M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 22 cartridge. PICC connection: W81x16. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 22: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR PICV 100-105-110 With PICC 11-12-13

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

IVAR

PICV 100-105-110 With PICC 11-12-13

Valve that keeps the flow rate constant during operation within a certain differential pressure range thanks to a membrane device with a contrast spring. Complete with two pockets G 1/4"F for piezometric sockets (IVAR AVB 10) and with plugs for piezometric sockets and cartridge. PICV 100 (female) connections: G 1"F, G 1"1/4F in compliance with ISO 228/1. PICV 105 (male - flat seal) connections: G 1"M, G 1"1/4M, G 1"1/2M in compliance with ISO 228/1. PICV 110 (with unions) connections: G 3/4"M, G 1"M, G 1"1/4M in compliance with ISO 228/1 and EN 10226-1. To combine with PICC 11, PICC 12 or PICC 13 cartridges. PICC connection: M54x1.5. Compatible with water or glycol solutions max 30%. Min operating temperature: -20 °C. Max operating temperature: 120 °C. Max operating pressure: 25 bar. Max closing pressure with PICC 13: 4 bar. Valve material: CW617N brass. Sealing gaskets material: Peroxide EPDM. IVAR PICC 11: 8 flow rate ranges to set; brass and POM insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 12: 41 flow rate ranges to set even during operation; brass and PSU insert; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets. IVAR PICC 13: 41 flow rate ranges to set even during operation; to combine with IVAR RV 03 axial motor (M30x1.5; 2 points/3 points 230 V AC or 2 points/3 points 24 V AC or proportional 0-10 V 24 V AC adjustment); max closing pressure 4 bar; brass and PSU/POM/PPS (glass-fibre reinforced) insert; stainless steel internal metal components; PPS/Peroxide EPDM cone; HNBR/Peroxide EPDM diaphragm; Peroxide EPDM sealing gaskets.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR IVARSAT-L-LE

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-L-LE

Satellite module that independently manages low-temperature heating (mixed circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR IVARSAT-HL-HLE

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-HL-HLE

Satellite module that independently manages high-temperature and low-temperature heating (direct and mixed circuits) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; mixing valve for fixed point mixing (with thermostatic control head and remote contact probe) or outside compensated temperature mixing (with axial servomotor and control unit); three-speed pump / model “E” with variable-speed pump EEI<20; summer/winter two-way valve on high-temperature and low-temperature circuits; pocket for temperature immersion probe on delivery side of primary circuit; balancing valve on primary circuit; balancing by-pass valve on mixed circuit; balancing lockshield of heating/domestic water circuit; hydraulic separator with built-in check valve; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. High-temperature domestic water outlet. Hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR IVARSAT-H

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

IVAR

IVARSAT-H

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR IVARSAT-H VNR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

IVAR

IVARSAT-H VNR

Satellite module that independently manages high-temperature heating (direct circuit) and instantaneous production of domestic hot water in each apartment when installed in district heating systems. Components: 30 plates heat exchanger; priority valve for domestic water circuit controlled by 230 V AC – 6 W motor; anti-scalding thermostatic mixing valve 36÷50 °C; domestic water preheating device; anti-scalding device on domestic hot water circuit; thermometer on domestic hot water circuit; anti-pollution check valve at the inlet of domestic cold water circuit; summer/winter two-way valve; pocket for temperature immersion probe on delivery side of primary circuit; balancing lockshield of primary circuit with double micrometrical adjustment; balancing lockshield of heating/domestic water circuit; differential overpressure by-pass valve on primary circuit; shut-off ball valve; manual air vent valve; fill-drain valves; protection filter for heat meter; expanded polypropylene insulating shell; multifunctional electronic board. Circuit connections: 3/4” flat seal. Indicative power (to be verified according to the conditions of use): 10 kW heating side, 32 kW domestic water side. Production of 12 l/min of 48°C domestic water. Model “1” with high-temperature domestic water outlet. Model “R” with hot domestic water recirculation circuit complete with pump, check valve and electronic temperature sensor for domestic hot water priority mode activation. Installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover (white painted) 860-960 × 700 × 110-160 mm, “M” in wall hanging box made of aluminium (white painted) 722 × 600 × 150 mm. Optional accessories: mechanical or ultrasonic heat meter 1,5 o 2,5 m3/h, cold domestic water flow meter 1,5 m3/h, thermoelectric actuator, thermostatic control head, axial servomotor. In compliance with Belgaqua.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR Dirtstop®

Dirtstop®

Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swiveling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the large settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swiveling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swiveling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swiveling insert in position A = 5,6 m3/h angle configuration; Kv with swiveling insert in position A1 = 6,2 m3/h straight configuration; Kv with swiveling insert in position B = 5,5 m3/h angle configuration; Kv with swiveling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

IVAR

Dirtstop®

Swivelling magnetic dirt separator with double filtering action, compact, with connection kit for the installation under the boiler. The double filtering action, guaranteed in any position thanks to the swiveling insert (Patent Pending), is performed by a neodymium magnet (magnetic induction B = 1,2 T (12.000 G)) and a mesh strainer (800 μm) made of AISI 304 stainless steel. The neodymium magnet is diametrically polarized and therefore it develops a homogeneous magnetic field which maximizes the capture of ferrous impurities. The mesh strainer retains all impurities. Impurities precipitate into the large settling chamber at the bottom of the dirt separator. The evacuation of impurities is possible without emptying the system and disassembling the dirt separator, thanks to the removable magnet and to the opening of a 360° swiveling shut-off ball valve. Body material: technopolymer IXEF®. Shut-off ball valve, swiveling fitting and plugs material: CW617N brass. Sealing elements material: Peroxide EPDM. Temperature: 0 ÷ 90 °C. Max pressure: 3 bars. Kv with swiveling insert in position A = 5,6 m3/h angle configuration; Kv with swiveling insert in position A1 = 6,2 m3/h straight configuration; Kv with swiveling insert in position B = 5,5 m3/h angle configuration; Kv with swiveling insert in position B1 =5,7 m3/h straight configuration. Compatible with water or glycol solutions max 50%. Connections: 3/4”M x 3/4"F.

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR CUBODOMO®

CUBODOMO®

Smart system for managing the heating system remotely via app. It allows remote control of all the zones in the house through time slots. Compatible with autonomous or centralized heating systems, at high or low temperature (e.g. radiators, radiant floor or ceiling, fan-coil). It can be used in public or private environment thanks to tamper controls. Installation of temperature sensors with no electrical connection. Temperature sensor with relay replaces the main chronothermostat and manages the switching on/off of the boiler (or zone valve with appropriate wiring). Operating system compatible with MyCubodomo App: Android 5.0 and iOS 8.0 onwards. Operating temperature range: -5 – 45 °C. Transmission frequency: 868,3 MHz. Signal range: 30 meters. Cube: power supply 5 V/1 A micro USB, Wi-Fi Standard FCC/CE/TELEC/KCC/SRRC/IC/NCC, protocollo Wi-Fi 802.11 b/g/n, frequency 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M), dimensions (W x H x D) 100 x 100 x 100 mm. Temperature sensor (with or without relay): power supply 2 alkaline batteries AA (mod. LR6) 1.5 V, hysteresis on the set point temperature On-Off +/- 0,1°C, average battery life 3 years, dimensions (W x H x D) 87 x 87 x 28 mm. Actuator: power supply 3 alkaline batteries AA (mod. LR6) 1.5 V, connection M30x1.5, maximum closing distance 12 mm, insulation CLASS III, average battery life 3 years. Dimensions (W x H x D) 92 x 48 x 66 mm. Wiring Center: control unit equipped with radio module, power supply 230V 50/60 Hz, fuses F3 15A/250V, output switching relay max 2A/230V AC - 2A/30V DC, dimensions (W x H x D) 180 x 130 x 65 mm.

IVAR

CUBODOMO®

Smart system for managing the heating system remotely via app. It allows remote control of all the zones in the house through time slots. Compatible with autonomous or centralized heating systems, at high or low temperature (e.g. radiators, radiant floor or ceiling, fan-coil). It can be used in public or private environment thanks to tamper controls. Installation of temperature sensors with no electrical connection. Temperature sensor with relay replaces the main chronothermostat and manages the switching on/off of the boiler (or zone valve with appropriate wiring). Operating system compatible with MyCubodomo App: Android 5.0 and iOS 8.0 onwards. Operating temperature range: -5 – 45 °C. Transmission frequency: 868,3 MHz. Signal range: 30 meters. Cube: power supply 5 V/1 A micro USB, Wi-Fi Standard FCC/CE/TELEC/KCC/SRRC/IC/NCC, protocollo Wi-Fi 802.11 b/g/n, frequency 2.4 GHz ~ 2.5 GHz (2400M ~ 2483.5M), dimensions (W x H x D) 100 x 100 x 100 mm. Temperature sensor (with or without relay): power supply 2 alkaline batteries AA (mod. LR6) 1.5 V, hysteresis on the set point temperature On-Off +/- 0,1°C, average battery life 3 years, dimensions (W x H x D) 87 x 87 x 28 mm. Actuator: power supply 3 alkaline batteries AA (mod. LR6) 1.5 V, connection M30x1.5, maximum closing distance 12 mm, insulation CLASS III, average battery life 3 years. Dimensions (W x H x D) 92 x 48 x 66 mm. Wiring Center: control unit equipped with radio module, power supply 230V 50/60 Hz, fuses F3 15A/250V, output switching relay max 2A/230V AC - 2A/30V DC, dimensions (W x H x D) 180 x 130 x 65 mm.

EMCS compliant

.RFA

Motor Control

IVAR

Download
IVAR VCR 2132 NH HARMONIA Thermostatic valve

VCR 2132 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring, G 1/2"F x G 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCR 2132 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring, G 1/2"F x G 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VS 2102 NH HARMONIA Thermostatic valve

VS 2102 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VS 2102 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VD 2105 NH HARMONIA Thermostatic valve

VD 2105 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VD 2105 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VCR 2136 NH HARMONIA Thermostatic valve

VCR 2136 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCR 2136 NH HARMONIA Thermostatic valve

Reverse thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VD 2101 NH HARMONIA Thermostatic valve

VD 2101 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VD 2101 NH HARMONIA Thermostatic valve

Straight thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCS 2162 NH SX – VCD 2162 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with female connection. Connection to iron pipe x Connection to radiator: 3/8"F x 3/8"M with or without O-ring, 1/2"F x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VCS 2166 NH SX – VCD 2166 NH DX HARMONIA Thermostatic valve

Co-axial left/right thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VS 2106 NH HARMONIA Thermostatic valve

VS 2106 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

IVAR

VS 2106 NH HARMONIA Thermostatic valve

Angle thermostatic valve with flow rate pre-regulation and pressure dynamic balancing, HARMONIA-series, with male connection. Connection to iron pipe x Connection to radiator: EUROK x 1/2"M with or without O-ring. Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Differential pressure range: 0.1÷0.6 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: Peroxide EPDM. Spring, washer and spindle material: Stainless steel. Protective cap: orange ABS.

EMCS compliant

.RFA

Valve for Heating and Cooling

IVAR

Download
IVAR VD 2101 Thermostatic valve

VD 2101 Thermostatic valve

Straight thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

IVAR

VD 2101 Thermostatic valve

Straight thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR VS 2102 Thermostatic valve

VS 2102 Thermostatic valve

Angle thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

IVAR

VS 2102 Thermostatic valve

Angle thermostatic valve with female connection. Connection to iron pipe x Connection to radiator: G 3/8"F x G 3/8"M with or without O-ring (with white protective cap or manual head), G 1/2"F x G 1/2"M with or without O-ring (with white protective cap or manual head), G 3/4"F x G 3/4"M with or without O-ring (with white protective cap or manual head), G 1"F x G 1"M with or without O-ring (with white protective cap), G 1"1/4F x G 1"1/4M with or without O-ring (with white protective cap). Flow rate pre-regulation only available for 3/8", 1/2" and 3/4" sizes: N-series (black protective cap or white manual head) or F-series (red protective cap or white manual head). Ring nut with spingle which can be replaced and inspected while the system is working. Fluid: water, glycol-water solutions (up to 30% glycol max). Max fluid temperature: 120° C. Max operating pressure: 10 bar. Max differential pressure: 1 bar. Max differential pressure with thermostatic head installed: 0.25 bar. Body material: nickel-plated CW617N brass. Gaskets and O-rings materials: peroxide EPDM. Spring, washer and spindle material: stainless steel. Protective cap and manual head material: ABS.

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI600N

BRASS-ROD MANIFOLDS CI600N

Flow manifold with flow meter/adjuster FLUXER (0-5 l/min) and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI600N

Flow manifold with flow meter/adjuster FLUXER (0-5 l/min) and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CS502N

BRASS-ROD MANIFOLDS CS502N

Plain manifold with EUROK connections. Manifolds can be used as supply or return manifolds. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CS502N

Plain manifold with EUROK connections. Manifolds can be used as supply or return manifolds. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI562MN

BRASS-ROD MANIFOLDS CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI562MN

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI552N

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI552N

Flow manifold with micrometric dually adjusted lockshields and EUROK connections. Manifolds can be used as supply manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C.Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI554MN

BRASS-ROD MANIFOLDS CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI554MN

Return manifold with manually operated isolation valves and EUROK connections. Manifolds can be used as return manifolds only. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 1 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS CI595MN

BRASS-ROD MANIFOLDS CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS CI595MN

Kit made of flow manifold with flow meter/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 90°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS KC01KC

BRASS-ROD MANIFOLDS KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS KC01KC

Kit made of flow manifold with double micrometric adjustment lockshields, return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR BRASS-ROD MANIFOLDS KC02KC

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

IVAR

BRASS-ROD MANIFOLDS KC02KC

Kit made of flow manifold with flow meters/adjusters FLUXER (0-5 l/min), return manifold with manually operated isolation valves, brackets, terminals, filling/drainage valves, air vent valves and EUROK connections. The body is made of brass CW617N. Nickel-plated outer finished or yellow outer finished.  Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar.  Main connections: G 1"F or G 1"1/4F. Secondary connections: EUROK. Sizes available: from 2 to 13 ways.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR METERING MODULES_EQUIMETER

METERING MODULES_EQUIMETER

Equimeter metering module with unit for heat only. Heat metering unit: Qn =1,5 m3/h (for modules with kv = 2,25); Qn =2,5 m3/h (for modules with kv = 2,75). MATERIALS Heat metering monoblock: CB753S brass. Shut-off valves: CW617N brass. Sealing elements: Peroxide EPDM. Cabinet: white painted galvanized steel sheet. Support: galvanized steel sheet. CONDITIONS OF USE Maximum static operating pressure: 10 bar. Maximum fluid temperature: 90 °C. CONNECTIONS G 3/4"M

IVAR

METERING MODULES_EQUIMETER

Equimeter metering module with unit for heat only. Heat metering unit: Qn =1,5 m3/h (for modules with kv = 2,25); Qn =2,5 m3/h (for modules with kv = 2,75). MATERIALS Heat metering monoblock: CB753S brass. Shut-off valves: CW617N brass. Sealing elements: Peroxide EPDM. Cabinet: white painted galvanized steel sheet. Support: galvanized steel sheet. CONDITIONS OF USE Maximum static operating pressure: 10 bar. Maximum fluid temperature: 90 °C. CONNECTIONS G 3/4"M

EMCS compliant

.RFA

Control Unit for Heating and Cooling

IVAR

Download
IVAR IVARSAT-H

IVARSAT-H

The satellite module IvarSAT-H independently manages high-temperature heating (direct circuit) in centralized systems and instantaneous production of domestic hot water in each apartment. Optional equipment: “R” with recirculation circuit complete with pump, “1” with high-temperature domestic water outlet. Mode of installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover painted white 860-960×700×110-160 mm, “M” in wall hanging box made of aluminium painted white 722×600×150 mm. Optional accessories: heat meter, flow meter, electrothermal head, thermostatic head, axial motor.

IVAR

IVARSAT-H

The satellite module IvarSAT-H independently manages high-temperature heating (direct circuit) in centralized systems and instantaneous production of domestic hot water in each apartment.
Optional equipment: “R” with recirculation circuit complete with pump, “1” with high-temperature domestic water outlet.
Mode of installation: on frame, “C” in wall fitted box made of galvanized sheet-metal cover painted white 860-960×700×110-160 mm, “M” in wall hanging box made of aluminium painted white 722×600×150 mm.
Optional accessories: heat meter, flow meter, electrothermal head, thermostatic head, axial motor.

EMCS compliant

.RFA

Distributor for Heating and Cooling

IVAR

Download
IVAR AC639 - Single bracket or EASY LOCK modular manifolds

AC639 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

IVAR

AC639 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR AC649 - Single bracket or EASY LOCK modular manifolds

AC649 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

IVAR

AC649 - Single bracket or EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Single bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Two different sizes: DN 20 or DN 25.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR CI400NB - Modular manifold EASY LOCK series

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NB - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR CS200N - Modular plain manifold EASY LOCK series

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CS200N - Modular plain manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 120°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR AC852 - Plastic box with bottom for modular manifolds

AC852 - Plastic box with bottom for modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Plastic box with bottom for modular manifolds (without fastening kit, to order separately). H: from 350 to 400 mm. W: from 350 to 800 mm. D: from 90 to 95 mm. With/without protection for plastering operations.

IVAR

AC852 - Plastic box with bottom for modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Plastic box with bottom for modular manifolds (without fastening kit, to order separately). H: from 350 to 400 mm. W: from 350 to 800 mm. D: from 90 to 95 mm. With/without protection for plastering operations.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR AC659N - Orientable terminal for EASY LOCK modular manifolds

AC659N - Orientable terminal for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Orientable terminal for EASY LOCK modular manifolds complete with drainage valve and automatic air vent valve. Material: nichel plated brass. Size: M 1/2".

IVAR

AC659N - Orientable terminal for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Orientable terminal for EASY LOCK modular manifolds complete with drainage valve and automatic air vent valve. Material: nichel plated brass. Size: M 1/2".

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR AC850 - Plastic box with bottom and fastening kit for coplanar and modular manifolds

AC850 - Plastic box with bottom and fastening kit for coplanar and modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Plastic box with bottom and fastening kit for coplanar and modular manifolds. Two different sizes: DN 20 or DN 25.

IVAR

AC850 - Plastic box with bottom and fastening kit for coplanar and modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).
Plastic box with bottom and fastening kit for coplanar and modular manifolds. Two different sizes: DN 20 or DN 25.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR CI400NR - Modular manifold EASY LOCK series

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

IVAR

CI400NR - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY-LOCK series. Manifolds can be used to supply DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 4 ways.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR CI350N - Modular manifold EASY LOCK series

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

IVAR

CI350N - Modular manifold EASY LOCK series

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Modular plain manifold EASY LOCK series. Manifolds can be used to supply DCW or DHW. The body is made of brass CW617N nickel-plated only externally. Gaskets and O-rings: Peroxide EPDM. Maximum fluid temperature: 100°C. Maximum operating pressure: 10 bar. Main connections: G 3/4"F or G 1"F. Secondary connections: EUROK or 1/2"M or 1/2"M TP (flat seal). Sizes available: from 2 to 5 ways.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR AC628 - Double bracket for EASY LOCK modular manifolds

AC628 - Double bracket for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves). Double bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Axle spacing: 200 mm. Two different sizes: DN 20 or DN 25.

IVAR

AC628 - Double bracket for EASY LOCK modular manifolds

The modular manifolds EASY LOCK series are characterised mainly by their ability to be connected to each other in an easy and practical way; threads are designed in order that EASY LOCK manifolds can be connected together having an aligned and sealed connection without using any sealing element. Manifolds are only externally nichel plated; therefore, yellow inside, making them suitable for drinking water use. They are available in several versions: with manually operated isolation valves (with blue or red hand wheel); with manually operated isolation valves (with blue or red hand wheel) and 30° inclined connections; plain (with no manually operated isolation valves).

Double bracket for EASY LOCK modular manifolds. Made of zinc plated steel. Axle spacing: 200 mm. Two different sizes: DN 20 or DN 25.

EMCS compliant

.RFA

Fitting for Sanitary and Sewerage

IVAR

Download
IVAR IVARPRESS – PRESS FITTINGS – Line

IVARPRESS – PRESS FITTINGS – Line

IVARPRESS is an IVAR press fitting studied and tested to be used with B crimper profile. The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product. The body is made of CW617N nickel-finished brass on the outer surface and yellow for all other parts in contact with fluid in conformity with the latest standards-regulations for drinking water plant. Available in a wide range of configurations and sizes.

IVAR

IVARPRESS – PRESS FITTINGS – Line

IVARPRESS is an IVAR press fitting studied and tested to be used with B crimper profile. The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product.
The body is made of CW617N nickel-finished brass on the outer surface and yellow for all other parts in contact with fluid in conformity with the latest standards-regulations for drinking water plant.
Available in a wide range of configurations and sizes.

EMCS compliant

.RVT .PDF

Distributor for Heating and Cooling

IVAR

Download
IVAR MPLC MULTI PRESS WITH LEAKAGE FUNCTION CUPHIN - Line

MPLC MULTI PRESS WITH LEAKAGE FUNCTION CUPHIN - Line

MULTI•PRESS•LEAK•CUPHIN is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting. Available in a wide range of configurations and sizes. Fitting body made of Cuphin CW724R.

IVAR

MPLC MULTI PRESS WITH LEAKAGE FUNCTION CUPHIN - Line

MULTI•PRESS•LEAK•CUPHIN is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting.
Available in a wide range of configurations and sizes.

Fitting body made of Cuphin CW724R.

EMCS compliant

.RVT .PDF

Distributor for Heating and Cooling

IVAR

Download
IVAR MPC MULTI PRESS CUPHIN - Line

MPC MULTI PRESS CUPHIN - Line

MULTI•PRESS•CUPHIN is an IVAR press fitting studied and tested to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product. Available in a wide range of configurations and sizes. Fitting body made of Cuphin CW724R.

IVAR

MPC MULTI PRESS CUPHIN - Line

MULTI•PRESS•CUPHIN is an IVAR press fitting studied and tested to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U).
The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product.
Available in a wide range of configurations and sizes.

Fitting body made of Cuphin CW724R.

EMCS compliant

.RVT .PDF

Fitting for Mechanical

IVAR

Download
IVAR MPL PRESS FITTINGS WITH LEAKAGE FUNCTION – Line

MPL PRESS FITTINGS WITH LEAKAGE FUNCTION – Line

MULTI•PRESS•LEAK is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting. Available in a wide range of configurations and sizes.

IVAR

MPL PRESS FITTINGS WITH LEAKAGE FUNCTION – Line

MULTI•PRESS•LEAK is the new press fitting designed to guarantee water leakage in case of failed pressing and to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U).
The absence of sealing if not pressed is a function which is especially on demand on the market to avoid problems and damage in case of forgotten pressing: thanks to the system test, the installer can immediately identify leaks and repair them by correctly pressing the fitting.
Available in a wide range of configurations and sizes.

EMCS compliant

.RVT .PDF

Distributor for Heating and Cooling

IVAR

Download
IVAR MP PRESS FITTINGS - Line

MP PRESS FITTINGS - Line

MULTI•PRESS is an IVAR press fitting studied and tested to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U). The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product. Available in a wide range of configurations and sizes.

IVAR

MP PRESS FITTINGS - Line

MULTI•PRESS is an IVAR press fitting studied and tested to be used indifferently with 7 different crimper profiles (BE, B, TH, R, H, F, U).
The geometry of the fitting, designed for ideal coupling between pipe and fitting ensuing pressing, and the windows on the bushing holder, to verify correct insertion of the pipe and two O-rings in peroxide EPDM on each terminal, are all details which help to guarantee the usability and reliability of the product.
Available in a wide range of configurations and sizes.

EMCS compliant

.RVT .PDF

Distributor for Heating and Cooling

IVAR

Download
IVAR IS-BOX

IS-BOX

IS-BOX is a box with a pair of pre-installed 3+1 and 4+1 outlet sanitary manifolds, suitable for wall recessing even in bathrooms covered with tiles or valuable materials. The reduced size allows it to be installed in brick or plasterboard walls with a minimum thickness of 60 mm. The manifolds are compatible with drinking water and the inlets can be shut off by screw sealing valves and replaceable headworks. Available in two colours (white and chrome), also in the completely inspectable version.

IVAR

IS-BOX

IS-BOX is a box with a pair of pre-installed 3+1 and 4+1 outlet sanitary manifolds, suitable for wall recessing even in bathrooms covered with tiles or valuable materials. The reduced size allows it to be installed in brick or plasterboard walls with a minimum thickness of 60 mm. The manifolds are compatible with drinking water and the inlets can be shut off by screw sealing valves and replaceable headworks. Available in two colours (white and chrome), also in the completely inspectable version.

EMCS compliant

.RFA .PDF

Distributor for Heating and Cooling

IVAR

Download
IVAR IVAR ESAT DUAL

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system. IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

IVAR

IVAR ESAT DUAL

IVAR E-SAT DUAL is a double heat exchanger satellite module which allows on-site production of DHW and hot water for the heating system, with only AFS connections and technical water supply/return. Thanks to the integrated electronics IVAR E-SAT modulates the technical water flow to guarantee a low return temperature to the boiler. The double exchanger solution, completely separating the centralized system from the domestic one, guarantees easy maintenance of the single user system. IVAR ESAT DUAL can be equipped with differential pressure valves and shut-off valves kit.

EMCS compliant

.RFA .PDF

Distributor for Heating and Cooling

IVAR

Download