Pompa di calore (aria/acqua), unità esterna deve essere combinata con VWL ..8/5 IS... o VWL ..7/5 IS…
È possibile combinare la pompa di calore con le seguenti centraline: sensoCOMFORT VRC 720 (f), multiMATIC VRC 700(f) o VWZ AI.
Pompa di calore (aria/acqua), unità esterna deve essere combinata con VWL ..8/5 IS... o VWL ..7/5 IS…
È possibile combinare la pompa di calore con le seguenti centraline: sensoCOMFORT VRC 720 (f), multiMATIC VRC 700(f) o VWZ AI.
Pompa di calore (aria/acqua), Monoblocco
È possibile combinare la pompa di calore con le seguenti centraline: sensoCOMFORT VRC 720 (f), multiMATIC VRC 700(f) o VWZ AI.
Pompa di calore (aria/acqua), Monoblocco
È possibile combinare la pompa di calore con le seguenti centraline: sensoCOMFORT VRC 720 (f), multiMATIC VRC 700(f) o VWZ AI.
Vacuum degasser for removal of dissolved gasses in heating and comfort cooling systems with automatic water-refilling. Max/min system pressure: +0,7 - 5 bar, PN10. Temp. Range: 0 – +70 °C. Allowed media: Water. Max system vol: 50 m3
Vacuum degasser for removal of dissolved gasses in heating and comfort cooling systems with automatic water-refilling. Max/min system pressure: +0,7 - 5 bar, PN10. Temp. Range: 0 – +70 °C. Allowed media: Water. Max system vol: 50 m3
Vacuum degasser for removal of dissolved gasses in cooling and freezing systems down to -10C. Max/min system pressure: +0,7 - 5 bar, PN10. Temp. Range: -10C - +70C. . Allowed media: Water, Glycol mix, saline solution, etc.
Vacuum degasser for removal of dissolved gasses in cooling and freezing systems down to -10C. Max/min system pressure: +0,7 - 5 bar, PN10. Temp. Range: -10C - +70C. . Allowed media: Water, Glycol mix, saline solution, etc.
Vacuum degasser for removal of dissolved gasses in heating and comfort cooling systems. Max/min system pressure: +0,7 - 5 bar, PN10. Temp. Range: 0 – +70 °C. Allowed media: Water, Ethanol. Max system vol: 50 m3
Vacuum degasser for removal of dissolved gasses in heating and comfort cooling systems. Max/min system pressure: +0,7 - 5 bar, PN10. Temp. Range: 0 – +70 °C. Allowed media: Water, Ethanol. Max system vol: 50 m3
Vacuum degasser for removal of dissolved gasses in heating and comfort cooling systems. Max/min system pressure: +0,7 - 2,5 bar, PN10. Temp. Range: 0 – +70 °C. Allowed media: Water, Ethanol. Max system vol: 25 m3
Vacuum degasser for removal of dissolved gasses in heating and comfort cooling systems. Max/min system pressure: +0,7 - 2,5 bar, PN10. Temp. Range: 0 – +70 °C. Allowed media: Water, Ethanol. Max system vol: 25 m3