SRC17ZMP-S

RAC Single system - Outdoor Unit - Connectable with wall mounted indoor unit Standard series, SRK17ZMP-S - Smallest capacity in wall mounted line-up. - Compact footprint. - Maximum piping length of 15m. - Wide range of operation down to -15 degC and up to 46 degC in cooling (24 degC in heating) - R410A refrigerant

Mitsubishi Heavy Industries Air-Conditioners Australia

SRC17ZMP-S

RAC Single system - Outdoor Unit
- Connectable with wall mounted indoor unit Standard series, SRK17ZMP-S
- Smallest capacity in wall mounted line-up.
- Compact footprint.
- Maximum piping length of 15m.
- Wide range of operation down to -15 degC and up to 46 degC in cooling (24 degC in heating)
- R410A refrigerant

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Heavy Industries Air-Conditioners Australia

Download

FDC112-155KXEN6 / KXES6

Micro KX6 Heat pump VRF outdoor Unit - Connect up to 8 indoor units/up to 150% capacity. - High efficiency with COP (in cooling) up to 4.0. - These units employs DC inverter compressors ONLY. - Total of all piping lengths is up to 100m. - Maximum pipe length from outdoor unit of 70m. - Maximum length of 9.52mm liquid pipe of 50m.

Mitsubishi Heavy Industries Air-Conditioners Australia

FDC112-155KXEN6 / KXES6

Micro KX6 Heat pump VRF outdoor Unit
- Connect up to 8 indoor units/up to 150% capacity.
- High efficiency with COP (in cooling) up to 4.0.
- These units employs DC inverter compressors ONLY.
- Total of all piping lengths is up to 100m.
- Maximum pipe length from outdoor unit of 70m.
- Maximum length of 9.52mm liquid pipe of 50m.

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Heavy Industries Air-Conditioners Australia

Download

PAC-FDUA200VG

Duct Connected - High static pressure - Indoor unit - Adjustable external static pressure by wired remote controller - Wide External Static Pressure from 10 to 200 Pa - Energy efficiency is improved by using DC fan motor & high efficient heat exchanger - Zoning system (AZ option): effective temperatures control of multiple rooms with one indoor duct unit - Quiet operation (sound pressure level of 45 dBA) is achieved thanks to DC fan motor - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side - Compatible with Wi-Fi (option) - R410A refrigerant

Mitsubishi Heavy Industries Air-Conditioners Australia

PAC-FDUA200VG

Duct Connected - High static pressure - Indoor unit
- Adjustable external static pressure by wired remote controller
- Wide External Static Pressure from 10 to 200 Pa
- Energy efficiency is improved by using DC fan motor & high efficient heat exchanger
- Zoning system (AZ option): effective temperatures control of multiple rooms with one indoor duct unit
- Quiet operation (sound pressure level of 45 dBA) is achieved thanks to DC fan motor
- Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving
- Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side
- Compatible with Wi-Fi (option)
- R410A refrigerant

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air-Conditioners Australia

Download

PAC-FDCA71VNX-W

Heat pump hyper inverter - Outdoor unit - Leading powerful heating capacity in the industry thanks to expansion valve control and twin rotary compressor technology - High efficiency in both cooling and heating - Wide range of operation down to -20 C in heating and -15 C in cooling - Advanced technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A - Design flexibility optimised with a compatible piping length up to 50 m and a precharged piping length of 30 m - Demand response enabled

Mitsubishi Heavy Industries Air-Conditioners Australia

PAC-FDCA71VNX-W

Heat pump hyper inverter - Outdoor unit
- Leading powerful heating capacity in the industry thanks to expansion valve control and twin rotary compressor technology
- High efficiency in both cooling and heating
- Wide range of operation down to -20 C in heating and -15 C in cooling
- Advanced technology contributing to environmental protection with a range operating with R32 (-W) and another with R410A
- Design flexibility optimised with a compatible piping length up to 50 m and a precharged piping length of 30 m
- Demand response enabled

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Heavy Industries Air-Conditioners Australia

Download

FDC-KXZRXE1

KXZRX Hi-COP Heat Recovery VRF outdoor unit -Simultaneous heating and cooling operations of individual indoor units. Maximum energy efficiency: COP 4.76 -Energy efficiency is maximised by employing Multi-port DC Inverter compressor with concentrated electric winding -Total piping length up to 1000m and a maximum pipe run of 160m. - Wide range of controls, central controls and BMS systems are available.

Mitsubishi Heavy Industries Air-Conditioners Australia

FDC-KXZRXE1

KXZRX Hi-COP Heat Recovery VRF outdoor unit
-Simultaneous heating and cooling operations of individual indoor units.
Maximum energy efficiency: COP 4.76
-Energy efficiency is maximised by employing Multi-port DC Inverter compressor with concentrated electric winding
-Total piping length up to 1000m and a maximum pipe run of 160m.
- Wide range of controls, central controls and BMS systems are available.

EMCS compliant

.DWG .RFA .IFC

Heat Pump

Mitsubishi Heavy Industries Air-Conditioners Australia

Download

PAC-FDUA200VH

Duct Connected - High static pressure - Indoor unit - Adjustable external static pressure by wired remote controller - Wide External Static Pressure from 10 to 200 Pa - Energy efficiency is improved by using DC fan motor & high efficient heat exchanger - Zoning system: effective temperatures control of multiple rooms with one indoor duct unit - Quiet operation (sound pressure level of 45 dBA) is achieved thanks to DC fan motor - Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving - Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side

Mitsubishi Heavy Industries Air-Conditioners Australia

PAC-FDUA200VH

Duct Connected - High static pressure - Indoor unit
- Adjustable external static pressure by wired remote controller
- Wide External Static Pressure from 10 to 200 Pa
- Energy efficiency is improved by using DC fan motor & high efficient heat exchanger
- Zoning system: effective temperatures control of multiple rooms with one indoor duct unit
- Quiet operation (sound pressure level of 45 dBA) is achieved thanks to DC fan motor
- Motion sensor (option): detects the presence/absence and human activity in a room to improve comfort and energy saving
- Impeller and motor can be pulled out easily and maintenance can be carried out from the right or bottom side

EMCS compliant

.DWG .RFA .IFC

Air Conditioner

Mitsubishi Heavy Industries Air-Conditioners Australia

Download