IVAR EQCP1 (Kv 2.50): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506587CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506587CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.
IVAR EQCP1 (Kv 3.00): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 130 mm and nominal flow rate Qnom = 2.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506539CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506539CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.
IVAR
IVAR EQCP1 (Kv 2.50): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506587CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506587CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.
IVAR EQCP1 (Kv 3.00): Two-way metering module for heating and cooling systems with DHW distribution lines and heat metering unit, equipped with template sockets instead of heat meters. Heat module consisting of CW617N brass monobloc with 2-way piston zone valve with M30×1.5 mm connection, selector balancing valve, filter, pocket for heat meter delivery sensor, M10×1 pressure pocket for dynamic balancing valve. Shut-off valves on the delivery and return to the boiler, on the delivery and return from the users, with slots for sealing. Drop pressure of the heat metering module Kv = 3.5. Placed on decomposable brackets and insulated with PP shell. Connections to the uprising columns and to the users of the G 3/4" heat module. Predisposition for heat meter with G 3/4" connections, length 130 mm and nominal flow rate Qnom = 2.5 m3/h. Domestic block with G 3/4" connections that can be intercepted with ball valves with sealing slots. Predisposition for insertion of DHW volumetric meters with G 3/4" connections, length 110 mm and nominal flow rate Qnom = 1.5 m3/h. Code 506539CB assembled in steel flush-mounted metal box with standard painted door, dimensions H 510 ×L 510 ×D 130 mm. Code 506539CL assembled in steel flush-mounted metal box with plasterable door, dimensions H 520 ×L 520 × D 130 mm. Max static operating pressure 10 bar; fluid temperature range 3÷90 ◦C.
EMCS compliant h4 >
.RVT .RFA
Unidad de control para calefacción y aire acondicionado
IVAR
Descargar