Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with:
- Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h.
- High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar.
- Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar.
- Variable-speed electronic pump WILO4F centre distance 130 mm.
- 3-speed standard pump WILO3F centre distance 130 mm.
- Polypropylene insulation shell.
- Wall fitted cabinet with variable height and depth.
- T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m.
- RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.
IVAR
Distribution and mixing system IVAR MULTIMIX for thermal power stations, modular with:
- Manifold made of CB753S brass from casting with adjustable and interceptable hydraulic separator integrated. Complete with union with swivel fittings G 1” for the connection to distribution kits, shut-off ball valves DN 25 at the inlets, thermomanometer 0-6 bar/0-120 ◦C and automatic air vent valve. 2-way or 3-way versions available. Possibility of connection to the primary circuit from above, below, right or left. Expandable by connecting to other manifolds with swivel nipples G 1”. Other components made of CW617N brass. Gaskets and o-rings made of Peroxide-cured EPDM. Connections to the primary circuit G 1”F, centre distance delivery/return 52 mm (inlet from the side), 197 mm (inlet from above or below, 2-way manifold), 170 mm (inlet from above or below, 3-way manifold); connections to the distribution circuits with swivel nut G 1”F, centre distance delivery/return 45 mm. Max operating temperature 120 ◦C. Max operating pressure 10 bar. Max primary circuit flow rate 3500 l/h.
- High-temperature direct flow kit complete with telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C; check valve. Primary circuit connections G 1” M, delivery/return centre distance 45 mm; distribution circuits connections G 3/4”F, delivery/return centre distance 90 mm. Parts from casting: CB753S brass. Other parts made of CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar.
- Low temperature mixing kit complete with 3-way mixing valve with headwork for thermostatic or motorisable control, secondary bypass with micrometric dually adjusted lockshields and position memory, telescopic system for pump connection, shut-off ball valves for pump connection, delivery and return thermometers 0÷80 ◦C, check valve, fixed setting safety thermostat 60◦C. Primary circuit connections (manifold-separator) G 1”M, centre distance delivery/return 45 mm; heating circuits connections G 3/4”F, centre distance delivery/return 90 mm. Parts from casting: CB753S brass. Other parts: CW617N brass. Gaskets and o-rings: peroxide-cured EPDM. Max operating temperature (pump excluded) 120 ◦C. Max operating pressure 10 bar.
- Variable-speed electronic pump WILO4F centre distance 130 mm.
- 3-speed standard pump WILO3F centre distance 130 mm.
- Polypropylene insulation shell.
- Wall fitted cabinet with variable height and depth.
- T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Connection: M30 x 1.5. Probe holder connection: 1/2". Range: 30-55 °C. Cable lenght: 2 m.
- RV 01: axial motor. Connection: M30 x 1.5. 3-point adjustment 230 V AC or 24 V AC or proportional 0-10 V 24 V AC.
EMCS compliant h4 >
.RVT .RFA
Distributor for Heating and Cooling
IVAR
Download